Dept. of Pharmaceutical Chemistry P. E. Society’s Modern College of Pharmacy Nigdi, Pune-411044, Maharashtra.
*E-mail: sbjadhav_pharma@yahoo.co.in
https://doi.org/10.53879/id.49.01.p0050
ABSTRACT
A simple, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed for the simultaneous estimation of olmesartan medoxomil and metoprolol succinate in tablet dosage form. A Phenomenex-C18, 5 mcm column 250 mm 4.6 mm in gradient mode, with mobile phase containing phosphate buffer, acetonitrile and methanol in proportion of 65:35 v/v, pH 5.5 adjusted with orthophosphoric acid were used. The flow rate was 1 mL/min, and effluent was monitored at 254 nm.The retention time of olmesartan medoxomil and metoprolol succinate were 8.02 and 5.36 min respectively, and the resolution factor was 9.0. Linearity range for olmesartan medoxomil and metoprolol succinate was 5-30 mcg mL-1 and 5-70 mcg mL-1 respectively. The proposed method is accurate, precise,specific and rapid for simultaneous estimation of olmesartan medoxomil and metoprolol succinate in tablet dosage form.